Caution

Working with high voltage is dangerous. Always follow local laws and regulations regarding high voltage work. If you are unsure about the rules in your country, consult a licensed electrician for more information.

Important

The EGMP battery platform cannot communicate over CAN. It only supports CAN FD!

Pinout on battery image image

image image image

Batterie Data (from Kia/Hyundai Service Manual) image

Batterie BMU/CMU Info image image image image image

Images etc.

Similar wiki: E-GMP platform

***** Below find pin connection required ****** 1,2,12 - 12v / 3+14 - shunt / 7+8 - resistor / 10+11 - can-fd (to MCP board) / 13 - 5v / 24+25 - shunt / 27+28 - resistor / 29+30 - resistor / 31+32+33 - gnd /

You also need to shunt the 3 interconnect in the 3 HV connectors. You can measure if the shunt is connected correctly with a voltmeter. If closed correctly the shunt should measure 2.5V