Remove power on behaviour for Z111PL0H-1JX/Woolley SA-028 #8503
base: master
Are you sure you want to change the base?
Conversation
@@ -950,13 +950,21 @@ const definitions: DefinitionWithExtend[] = [ | |||
exposes: [e.cover_position(), e.battery()], | |||
}, | |||
{ | |||
zigbeeModel: ['Z111PL0H-1JX', 'SA-029-1', 'SA-028-1'], | |||
zigbeeModel: ['SA-029-1', 'SA-028-1'], | |||
model: 'SA-028/SA-029', | |||
vendor: 'SONOFF', | |||
whiteLabel: [{vendor: 'Woolley', model: 'SA-029-1'}], | |||
description: 'Smart Plug', | |||
extend: [onOff(), forcePowerSource({powerSource: 'Mains (single phase)'})], |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Please add it to here instead, I guess the SA-029 and SA-028 also don't support it.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Thanks for the review. Though seems like there are different versions/firmware of the SA-028 is being sold. One with power on behavior (SA-028 modelId) and one without (Z111PL0H-1JX) with exactly the same packaging and plug type.
Cant say for SA-029 since I don't have one on hand, it is suppose to be only a different socket type but then who knows what they decide to enable on the firmware 🙃
This is the db entry for the other SA-028 with power on behavior
{"id":117,"type":"Router","ieeeAddr":"0x7cb94c61881d0000","nwkAddr":22814,"manufId":4742,"manufName":"Sonoff","powerSource":"Mains (single phase)","modelId":"SA-028-1","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":9,"inClusterList":[0,3,4,5,6,4096,64599,64672],"outClusterList":[25],"clusters":{"genBasic":{"attributes":{"stackVersion":0,"hwVersion":0,"zclVersion":8}},"genOnOff":{"attributes":{"onOff":0,"startUpOnOff":255}}},"binds":[{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b002f8b1364","endpointID":1},{"cluster":25,"type":"endpoint","deviceIeeeAddress":"0x00124b002f8b1364","endpointID":1}],"configuredReportings":[{"cluster":6,"attrId":0,"minRepIntval":0,"maxRepIntval":65000,"repChange":1}],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":1,"stackVersion":0,"hwVersion":0,"dateCode":"20210610-BL","swBuildId":"1.0.5","zclVersion":8,"interviewCompleted":true,"meta":{"configured":332242049},"lastSeen":1734895050344}
Anyhow I saw there's the S26R2ZB without power on behavior maybe I can move the Z111PL0H-1JX there as another SA-028 white label w/o pob? Instead of creating a completely new/separate model for this to pass the test Wdyt? And leave the SA-028/SA-029 as is.
Co-authored-by: Koen Kanters <[email protected]>
Got a couple more of these Woolley plugs, though seems like this batch I got with the model Z111PL0H-1JX identifier do not have power on behavior. (also mentioned by Koenkk/zigbee2mqtt#10282 (comment))
db entry:
When trying to set power on behavior: