Notifications
You must be signed in to change notification settings - Fork 97
Chlorinator
kjf77 edited this page Feb 19, 2024
·
2 revisions
This page is for the Pentair and Hayward (aka AquaRite, NatureSoft, MineralSprings, SmartPure, etc) Salt Chlorinator
These packets are a little different than all of the others in this wiki. They all start with 16,2 and end with 16,3. There is no high bit checksum (only a low bit).
If you are wiring this yourself, the pinouts are also slightly different than the other pool peripherals.
Aquarite pins:
1=Red=Power
2=Blk = data +
3=Ylw= data -
4=Grn=Ground
Command | Name |
---|---|
0 | Get Status |
1 | Response to Get Status |
3 | Response to Get Version |
17 | Set Salt % |
18 | Response to Set Salt % & Salt PPM |
20 | Get Version |
21 | Set Salt Generate % / 10 |
Byte | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
---|---|---|---|---|---|---|---|---|---|
Request | 16 | 2 | 80 | 0 | 0 | 98 | 16 | 3 | |
Response | 16 | 2 | 0 | 1 | 0 | 0 | 19 | 16 | 3 |
Byte | Known? | Sample | Definition |
---|---|---|---|
1 | Y | 16 | Preamble 1 |
2 | Y | 2 | Preamble 2 |
3 | Y | 80 | Destination = Chlorinator |
4 | Y | 0 | Command = Get Status |
5 | N | 0 | Not sure |
6 | Y | 98 | Checksum Low Bit |
7 | Y | 16 | Post-amble 1 |
8 | Y | 3 | Post-amble 2 |
Byte | Known? | Sample | Definition |
---|---|---|---|
1 | Y | 16 | Preamble 1 |
2 | Y | 2 | Preamble 2 |
3 | Y | 0 | Destination = Controller |
4 | Y | 1 | Status = Ok |
5 | N | 0 | Not sure |
6 | N | 0 | Not sure |
7 | Y | 19 | Checksum Low Bit |
8 | Y | 16 | Post-amble 1 |
9 | Y | 3 | Post-amble 2 |
Byte | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
---|---|---|---|---|---|---|---|---|---|
Request | 16 | 2 | 80 | 17 | 3 | 118 | 16 | 3 | |
Response | 16 | 2 | 0 | 18 | 58 | 144 | 238 | 16 | 3 |
Byte | Known? | Sample | Definition |
---|---|---|---|
1 | Y | 16 | Preamble 1 |
2 | Y | 2 | Preamble 2 |
3 | Y | 80 | Destination = Chlorinator |
4 | Y | 17 | Command = Set Salt % If this is 21, then bit 5 = Set Salt %/10. |
5 | Y | 3 | Set Salt % (3%) If bit 4 is 21, then divide this by 10 (EG 100/10=10%); |
6 | Y | 118 | Checksum Low Bit, This bit is checksum of 1-5 bits (MOD 256, if necessary) |
7 | Y | 16 | Post-amble 1 |
8 | Y | 3 | Post-amble 2 |
Byte | Known? | Sample | Definition |
---|---|---|---|
1 | Y | 16 | Preamble 1 |
2 | Y | 2 | Preamble 2 |
3 | Y | 0 | Destination = Controller |
4 | Y | 18 | Status = Salt PPM Command |
5 | Y | 58 | Salt PPM * 50 (58*50=2,900PPM) |
6 | Y | 144 | Error bit: 0=Ok, 1=No Flow, 2=Low Salt, 4=High Salt, 144=Clean Salt Cell |
7 | Y | 238 | Checksum Low Bit |
8 | Y | 16 | Post-amble 1 |
9 | Y | 3 | Post-amble 2 |
Byte | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Request | 16 | 2 | 80 | 20 | 2 | 120 | 16 | 3 | ||||||||||||||||
Response | 16 | 2 | 0 | 3 | 0 | 73 | 110 | 116 | 101 | 108 | 108 | 105 | 99 | 104 | 108 | 111 | 114 | 45 | 45 | 52 | 48 | 188 | 16 | 3 |
Byte | Known? | Sample | Definition |
---|---|---|---|
1 | Y | 16 | Preamble 1 |
2 | Y | 2 | Preamble 2 |
3 | Y | 80 | Destination = Chlorinator |
4 | Y | 20 | Command = Get Name |
5 | N | 2 | Not sure. Intellitouch uses 2. Aquarite uses 0. Any of them seem to work. |
6 | Y | 120 | Checksum Low Bit, This bit is checksum of 1-5 bits (MOD 256, if necessary) |
7 | Y | 16 | Post-amble 1 |
8 | Y | 3 | Post-amble 2 |
Byte | Known? | Sample | Definition |
---|---|---|---|
1 | Y | 16 | Preamble 1 |
2 | Y | 2 | Preamble 2 |
3 | Y | 0 | Destination = Controller |
4 | Y | 3 | Command = Return Name |
5 | Y | 58 | Salt PPM * 50 (58*50=2,900PPM) |
6-21 | Y | many | Ascii bits. This example returns "Intellichlor--40" |
22 | Y | 188 | Checksum Low Bit |
23 | Y | 16 | Post-amble 1 |
24 | Y | 3 | Post-amble 2 |