Notifications
You must be signed in to change notification settings - Fork 480
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Add initial support for Tornado 16X SQ air conditioner (0x4e2a) #430
Conversation
Thank you very much for the contribution! If you try to control it with the hysen class, does it work? |
It's the first thing I tried, but it fails, the payloads are different in size, info and don't use a CRC for checksum. Figuring out the values in the payload took me the most time, your broadlink-hacktools was invaluable. |
Sorry for asking all this. You had already done a great job of cracking the codes. But if I change the code after we merge this I won't be able to test the changes because I don't have the device. |
broadlink/climate.py
Outdated
data['display'] = (payload[0x16] & 0x10 == 0x10) | ||
data['health'] = (payload[0x14] & 0b11 == 0b11) | ||
|
||
checksum = self._calculate_checksum(payload[:0x19]) # checksum=(payload[0x1a] << 8) + payload[0x19] |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
How about something like this?
checksum = payload[0x19] | (payload[0x1a] << 8)
if sum(payload[:0x19], 0x20017) - sum(payload[0x19:0x1b]) & 0xffff != checksum:
raise exception(-4008) # Checksum error.
Are you sure 0x20017 is not an int (20017)? Please double check, this number does not feel right.
If so, you can use this:
checksum = payload[0x19] | (payload[0x1a] << 8)
if sum(payload[:0x19], 0x4e31) - sum(payload[0x19:0x1b]) & 0xffff != checksum:
raise exception(-4008) # Checksum error.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I don't fully understand how the checksum works, but I've done a lot of testing with this implementation without a problem showing up, will gladly send packet captures if you want to try. I'm pretty certain it's not a straight sum like your example.
Sorry for asking all this. You had already done a great job of cracking the codes. But if I change the code after we merge this I won't be able to test the changes because I don't have the device.
It's actually nice to have someone looking over my code as I don't have a lot of experience.
Hi guys |
@thewh1teagle download the repo, checkout the branch, build the wheel, and install with pip. |
Thanks. I used @enosh Fork (Tornado branch), I installed it with |
Mind fixing the conflicts @enosh? |
Hi Edit
on Tornado 12X SQ air conditioner. |
broadlink/climate.py
Outdated
args = received_state | ||
logging.debug("filled args %s", args) | ||
|
||
PREFIX = [0xbb, 0x00, 0x06, 0x80, 0x00, 0x00, 0x0f, 0x00, |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think we can assume that all requests start with bb 00 06 80
(and responses with bb 00 07 00
). We can abstract this with self._encode() and self._decode(), respectively.
broadlink/climate.py
Outdated
data['mode'] = { | ||
0x00: 'auto', | ||
0x20: 'cooling', | ||
0x40: 'drying', | ||
0x80: 'heating', | ||
0xc0: 'fan' | ||
}.get(payload[0x11] &~ 0b111, 'unrecognized value') # noqa E225 |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
My opinion on how to handle this like a boss. Import the IntEnum class and create child classes inside the controller class. So we would end up with something like this:
from enum import IntEnum, unique
class sq1:
@unique
class Mode(IntEnum):
AUTO = 0
COOLING = 0x20
DRYING = 0x40
HEATING = 0x80
FAN = 0xc0
We can generate the mode in many different ways...
mode = self.Mode.FAN
mode = self.Mode["FAN"]
mode = self.Mode(0xc0)
We can use:
# For reading
mode = self.Mode(payload[0x11] &~ 0b111)
# For writing
packet[0xf] = mode | sleep << 2
This is like creating an interface for a normal integer.
# If we want to see the name
>>> mode.name
'COOLING'
# If we want to see the value
>>> mode.value
32
A ValueError is generated for invalid input:
>>> d = blk.hello("192.168.0.16") # Example HVAC
>>> d.Mode(1000)
Traceback (most recent call last):
File "<pyshell#59>", line 1, in <module>
d.Mode(1000)
File "/usr/lib/python3.6/enum.py", line 293, in __call__
return cls.__new__(cls, value)
File "/usr/lib/python3.6/enum.py", line 535, in __new__
return cls._missing_(value)
File "/usr/lib/python3.6/enum.py", line 548, in _missing_
raise ValueError("%r is not a valid %s" % (value, cls.__name__))
ValueError: 1000 is not a valid Mode
External applications have access to an interface. They can see what options they have.
>>> d = blk.hello("192.168.0.16") # Example HVAC
>>> [m for m in d.Mode.__members__]
['AUTO', 'COOLING', 'DRYING', 'HEATING', 'FAN']
Best of all: this is a normal integer that can be appended to the packet and serialized normally. What do you think?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I like it! Will implement.
Would you then pass a Mode object in the dictionary as input or the string representation?
Hi @enosh. Thanks again for this. I will solve conflicts and create a PR to the dev branch, we will continue from there, ok? Do you want to create the PR? |
Any update on this? does the library supports tornado ACs? |
Proposed changes
Add support for Tornado 16X SQ air conditioner (sold in Israel link). I think it'll also work for related models. Their app is based on AC Freedom so it might work with some models from that brand also. There are features like sleep curves, timers and ambient temperature I didn't implement.