#!/usr/bin/env python3
import sys
import os
import time
from rd6006 import RD6006
from ut61e import UT61E
def get_v_out(rd):
return rd._read_register(10)/100
def get_i_out(rd):
return rd._read_register(11)/1000
def check_device_file(fn):
try:
os.stat(fn)
except Exception as e:
print("Problem with serial port %s: %s" % (fn, str(e)), file=sys.stderr)
sys.exit(2)
def read_dmm_voltage(dmm):
dmm_v1 = dmm.get_meas()['val']
dmm_v2 = dmm.get_meas()['val']
dmm_v3 = dmm.get_meas()['val']
return min(dmm_v1, dmm_v2, dmm_v3)
def main():
if len(sys.argv) < 4:
print("Usage %s [PSU_SERIAL_PORT] [DMM_SERIAL_PORT] [OUTPUT_FILE]" % sys.argv[0], file=sys.stderr)
sys.exit(1)
max_voltage = 62 # adjust as needed!
psu_serial_port = sys.argv[1]
dmm_serial_port = sys.argv[2]
output_filename = sys.argv[3]
check_device_file(psu_serial_port)
check_device_file(dmm_serial_port)
rd = RD6006(psu_serial_port)
dmm = UT61E(dmm_serial_port)
# set initial current limit and zero voltage, then wait for PSU to settle
rd.current = 0.1
rd.voltage = 0
time.sleep(2)
with open(output_filename, "w") as fh:
print('#v_set\tv_disp,\tv_dmm', file=fh)
for v in range(0, max_voltage+1):
rd.voltage = v
time.sleep(0.3) # wait for PSU to settle
dmm_v = read_dmm_voltage(dmm) # read DMM voltage
disp_v = get_v_out(rd) # read PSU display voltage
err = disp_v - dmm_v
# simpler than piping through tee(1) and then having
# to deal with buffering etc
print("%f\t%f\t%f\t%f" % (v, disp_v, dmm_v, err))
print("%f\t%f\t%f\t%f" % (v, disp_v, dmm_v, err), file=fh)
# save the PSU before exiting
rd.current = 0
rd.voltage = 0
if __name__ == "__main__":