title | summary | aliases | |
---|---|---|---|
Secure TiDB Dashboard |
Learn how to improve the security of TiDB Dashboard. |
|
Although you need to sign into TiDB Dashboard before accessing it, TiDB Dashboard is designed to be accessed by trusted user entities by default. When you want to provide TiDB Dashboard to external network users or untrusted users for access, take the following measures to avoid security vulnerabilities.
The account system of TiDB Dashboard is consistent with that of TiDB SQL users. By default, TiDB's root
user has no password, so accessing TiDB Dashboard does not require password authentication, which will give the malicious visitor high privileges, including executing privileged SQL statements.
It is recommended that you set a strong password for TiDB root
user. See TiDB User Account Management for details.
TiDB Dashboard provides services through the PD client port, which defaults to http://IP:2379/dashboard/. Although TiDB Dashboard requires identity authentication, other privileged interfaces (such as http://IP:2379/pd/api/v1/members) in PD carried on the PD client port do not require identity authentication and can perform privileged operations. Therefore, exposing the PD client port directly to the external network is extremely risky.
It is recommended that you take the following measures:
-
Use a firewall to prohibit a component from accessing any client port of the PD component via the external network or untrusted network.
Note:
TiDB, TiKV, and other components need to communicate with the PD component through the PD client port, so do not block access to the internal network between components. Otherwise, the cluster will become unavailable.
-
See Use TiDB Dashboard behind a Reverse Proxy to learn how to configure the reverse proxy to safely provide the TiDB Dashboard service on another port to the external network.
Warning:
This section describes an unsafe access solution, which is for the test environment only. DO NOT use this solution in the production environment.
In the test environment, you might need to configure the firewall to open the TiDB Dashboard port for external access.
When multiple PD instances are deployed, only one of the PD instances actually runs TiDB Dashboard, and browser redirection occurs when you access other PD instances. Therefore, you need to ensure that the firewall is configured with the correct IP address. For details of this mechanism, see Deployment with multiple PD instances.
When using the TiUP deployment tool, you can view the address of the PD instance that actually runs TiDB Dashboard by running the following command (replace CLUSTER_NAME
with the cluster name):
{{< copyable "shell-regular" >}}
tiup cluster display CLUSTER_NAME --dashboard
The output is the actual TiDB Dashboard address.
Note:
This feature is available only in the later version of the
tiup cluster
deployment tool (v1.0.3 or later).Upgrade TiUP Cluster
{{< copyable "shell-regular" >}}
tiup update --self tiup update cluster --force
The following is a sample output:
http://192.168.0.123:2379/dashboard/
In this example, the firewall needs to be configured with inbound access for the 2379
port of the 192.168.0.123
open IP, and the TiDB Dashboard is accessed via http://192.168.0.123:2379/dashboard/.
As mentioned in [Use a firewall to block untrusted access](#use-a-firewall-to-block-untrusted access), the services provided under the PD client port include not only TiDB Dashboard (located at http://IP:2379/dashboard/), but also other privileged interfaces in PD (such as http://IP:2379/pd/api/v1/members). Therefore, when using a reverse proxy to provide TiDB Dashboard to the external network, ensure that the services ONLY with the /dashboard
prefix are provided (NOT all services under the port) to avoid that the external network can access the privileged interface in PD through the reverse proxy.
It is recommended that you see Use TiDB Dashboard behind a Reverse Proxy to learn a safe and recommended reverse proxy configuration.