From 01c66181e39d211958f5b39c7269ab6b32e16cfb Mon Sep 17 00:00:00 2001 From: gonz102 Date: Wed, 11 Dec 2024 18:45:58 -0500 Subject: [PATCH] Increased flow rate in 19-19e to ensure it fails conservatively (was incorreclty passing due to precision comparison) --- .../ashrae9012019/section19/rule_19_19.json | 92 ++++++++++--------- 1 file changed, 50 insertions(+), 42 deletions(-) diff --git a/rct229/ruletest_engine/ruletest_jsons/ashrae9012019/section19/rule_19_19.json b/rct229/ruletest_engine/ruletest_jsons/ashrae9012019/section19/rule_19_19.json index 13ede68273..33cbe8e58c 100644 --- a/rct229/ruletest_engine/ruletest_jsons/ashrae9012019/section19/rule_19_19.json +++ b/rct229/ruletest_engine/ruletest_jsons/ashrae9012019/section19/rule_19_19.json @@ -193,11 +193,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ] } @@ -205,6 +201,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -249,11 +250,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ], "zonal_exhaust_fan": { @@ -266,6 +263,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -349,11 +351,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ] } @@ -361,6 +359,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -405,11 +408,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ], "zonal_exhaust_fan": { @@ -422,6 +421,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -511,11 +515,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ], "non_mechanical_cooling_fan_airflow": 117.98686079999996 @@ -524,6 +524,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -568,11 +573,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ], "zonal_exhaust_fan": { @@ -585,6 +586,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -634,7 +640,7 @@ "Section": 19, "Rule": 19, "Test": "e", - "test_description": "The project has one building segment with one zone served by a baseline system type 10. The system has one of each of a supply, return, exhaust, and relief fan as well as a zonal exhaust fan. Each of the 5 fans has 80 W design electric power for a total of 400 W with 800 cfm of design supply airflow.", + "test_description": "The project has one building segment with one zone served by a baseline system type 10. The system has one of each of a supply, return, exhaust, and relief fan as well as a zonal exhaust fan. Each of the 5 fans has 80 W design electric power for a total of 400 W with 2000 cfm of design supply airflow.", "expected_rule_outcome": "fail", "expected_raised_message_includes": "fails with a conservative outcome. The fan power airflow (W/cfm) for", "standard": { @@ -668,11 +674,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ] } @@ -680,6 +682,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -724,11 +731,7 @@ "id": "Air Terminal", "is_supply_ducted": true, "type": "CONSTANT_AIR_VOLUME", - "served_by_heating_ventilating_air_conditioning_system": "System 10", - "heating_source": "ELECTRIC", - "fan": { - "id": "Terminal Fan 1" - } + "served_by_heating_ventilating_air_conditioning_system": "System 10" } ], "zonal_exhaust_fan": { @@ -741,6 +744,11 @@ "heating_ventilating_air_conditioning_systems": [ { "id": "System 10", + "heating_system": { + "id": "Furnace Coil 1", + "type": "ELECTRIC_RESISTANCE", + "energy_source_type": "ELECTRICITY" + }, "fan_system": { "id": "CAV Fan System 1", "fan_control": "CONSTANT", @@ -749,7 +757,7 @@ "id": "Supply Fan 1", "specification_method": "SIMPLE", "design_electric_power": 80, - "design_airflow": 755.1159091199997 + "design_airflow": 943.8948863999997 } ], "return_fans": [