diff --git a/database_files/hvac_minimum_requirement_water_heaters_IECC.json b/database_files/hvac_minimum_requirement_water_heaters_IECC.json new file mode 100644 index 0000000..b56bb94 --- /dev/null +++ b/database_files/hvac_minimum_requirement_water_heaters_IECC.json @@ -0,0 +1,3830 @@ +[ + { + "template": "IECC-2006", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.97, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 40944.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": 155, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": 1.73, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.67, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000.01, + "maximum_capacity": 155000, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 155000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 50000.01, + "maximum_capacity": 199999.99, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.62, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 105000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 105000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 210000, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000.01, + "maximum_capacity": 12499999.99, + "minimum_storage": 10.01, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000.01, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Pool Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Pool Heaters", + "fuel_type": "Oil", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Heat Pump Pool Heaters", + "fuel_type": "Electricity", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": 4, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2006", + "product_class": "Unfired Storage Tanks", + "fuel_type": "None", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": 12.5, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.97, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 40944.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": 155, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": 1.73, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.67, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000.01, + "maximum_capacity": 155000, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 155000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 50000.01, + "maximum_capacity": 199999.99, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.62, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 105000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 105000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 210000, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000.01, + "maximum_capacity": 12499999.99, + "minimum_storage": 10.01, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000.01, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Pool Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Pool Heaters", + "fuel_type": "Oil", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Heat Pump Pool Heaters", + "fuel_type": "Electricity", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": 4, + "r_value": null, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2009", + "product_class": "Unfired Storage Tanks", + "fuel_type": "None", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": 12.5, + "annotation": "From Table 504.2" + }, + { + "template": "IECC-2012", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.97, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 40944.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": 155, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": 1.73, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.67, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000.01, + "maximum_capacity": 155000, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 155000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 50000.01, + "maximum_capacity": 199999.99, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.62, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 105000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 105000, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 210000, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000.01, + "maximum_capacity": 12499999.99, + "minimum_storage": 10.01, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000.01, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Pool Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Pool Heaters", + "fuel_type": "Oil", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Heat Pump Pool Heaters", + "fuel_type": "Electricity", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": 4, + "r_value": null, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2012", + "product_class": "Unfired Storage Tanks", + "fuel_type": "None", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": 12.5, + "annotation": "From Table 404.2" + }, + { + "template": "IECC-2015", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.97, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 40944.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": 0.3, + "hourly_loss_volume_allowance": 27, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.67, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000.01, + "maximum_capacity": 155000, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 155000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 50000.01, + "maximum_capacity": 199999.99, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.62, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 105000, + "minimum_storage": 20, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 105000, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 210000, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000.01, + "maximum_capacity": 12499999.99, + "minimum_storage": 10.01, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000.01, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Pool Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.82, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Pool Heaters", + "fuel_type": "Oil", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.82, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Heat Pump Pool Heaters", + "fuel_type": "Electricity", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": 4, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2015", + "product_class": "Unfired Storage Tanks", + "fuel_type": "None", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": 12.5, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Table Top Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": 20, + "maximum_storage": 120, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.93, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": 20, + "maximum_storage": 55, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.96, + "energy_factor_volume_derate": 0.0003, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Grid Enabled Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": 75.01, + "maximum_storage": 120, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 1.061, + "energy_factor_volume_derate": 0.00168, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 40944.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": 0.3, + "hourly_loss_volume_allowance": 27, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 20, + "maximum_storage": 55, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.675, + "energy_factor_volume_derate": 0.0015, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 55.01, + "maximum_storage": 100, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.8012, + "energy_factor_volume_derate": 0.00078, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000.01, + "maximum_capacity": 155000, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 155000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 50000.01, + "maximum_capacity": 199999.99, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.82, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 105000, + "minimum_storage": 20, + "maximum_storage": 50, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.68, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 105000, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 210000, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000.01, + "maximum_capacity": 12499999.99, + "minimum_storage": 10.01, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000.01, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Pool Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.82, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Pool Heaters", + "fuel_type": "Oil", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.82, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Heat Pump Pool Heaters", + "fuel_type": "Electricity", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": 4, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2018", + "product_class": "Unfired Storage Tanks", + "fuel_type": "None", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": 12.5, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Table Top Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": 20, + "maximum_storage": 120, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.93, + "energy_factor_volume_derate": 0.00132, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": 20, + "maximum_storage": 55, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.96, + "energy_factor_volume_derate": 0.0003, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Grid Enabled Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 0, + "maximum_capacity": 40944, + "minimum_storage": 75.01, + "maximum_storage": 120, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 1.061, + "energy_factor_volume_derate": 0.00168, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Water Heaters", + "fuel_type": "Electricity", + "minimum_capacity": 40944.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": 0.3, + "hourly_loss_volume_allowance": 27, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 20, + "maximum_storage": 55, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.675, + "energy_factor_volume_derate": 0.0015, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 0, + "maximum_capacity": 75000, + "minimum_storage": 55.01, + "maximum_storage": 100, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.8012, + "energy_factor_volume_derate": 0.00078, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 75000.01, + "maximum_capacity": 155000, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Storage Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 155000.01, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 50000.01, + "maximum_capacity": 199999.99, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.82, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": 200000, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 105000, + "minimum_storage": 20, + "maximum_storage": 50, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.68, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Storage Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 105000, + "maximum_capacity": 99999999, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": 0, + "maximum_capacity_per_storage": 3999.99, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 0, + "maximum_capacity": 210000, + "minimum_storage": 0, + "maximum_storage": 1.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": 0.59, + "energy_factor_volume_derate": 0.0019, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Instantaneous Water Heaters", + "fuel_type": "Oil", + "minimum_capacity": 210000.01, + "maximum_capacity": 99999999, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 0, + "maximum_storage": 9.99, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "NaturalGas", + "minimum_capacity": 300000, + "maximum_capacity": 12499999.99, + "minimum_storage": 10, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.8, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Hot Water Supply Boilers", + "fuel_type": "Oil", + "minimum_capacity": 300000.01, + "maximum_capacity": 12499999.99, + "minimum_storage": 10.01, + "maximum_storage": 99999999, + "minimum_capacity_per_storage": 4000.01, + "maximum_capacity_per_storage": 99999999, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": 800, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": 110, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.78, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Pool Heaters", + "fuel_type": "NaturalGas", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.82, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Pool Heaters", + "fuel_type": "Oil", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": 0.82, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Heat Pump Pool Heaters", + "fuel_type": "Electricity", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": 4, + "r_value": null, + "annotation": "From Table C404.2" + }, + { + "template": "IECC-2021", + "product_class": "Unfired Storage Tanks", + "fuel_type": "None", + "minimum_capacity": null, + "maximum_capacity": null, + "minimum_storage": null, + "maximum_storage": null, + "minimum_capacity_per_storage": null, + "maximum_capacity_per_storage": null, + "draw_profile": null, + "start_date": "9/9/1919", + "end_date": "9/9/2999", + "energy_factor_base": null, + "energy_factor_volume_derate": null, + "standby_loss_base": null, + "standby_loss_capacity_allowance": null, + "standby_loss_volume_allowance": null, + "standby_loss_square_root_volume_allowance": null, + "hourly_loss_base": null, + "hourly_loss_volume_allowance": null, + "thermal_efficiency": null, + "uniform_energy_factor": null, + "uniform_energy_factor_base": null, + "uniform_energy_factor_volume_allowance": null, + "cop": null, + "r_value": 12.5, + "annotation": "From Table C404.2" + } +] \ No newline at end of file diff --git a/database_tables/__init__.py b/database_tables/__init__.py index 971582b..43befd3 100644 --- a/database_tables/__init__.py +++ b/database_tables/__init__.py @@ -11,6 +11,7 @@ # tables no foreign keys "hvac_minimum_requirement_motors_90_1", "hvac_minimum_requirement_water_heaters_90_1", + "hvac_minimum_requirement_water_heaters_IECC", "hvac_minimum_requirement_heat_rejection_90_1", "hvac_minimum_requirement_water_source_heat_pumps_cooling_90_1", "hvac_minimum_requirement_water_source_heat_pumps_heating_90_1", diff --git a/database_tables/hvac_minimum_requirement_water_heaters_IECC.py b/database_tables/hvac_minimum_requirement_water_heaters_IECC.py new file mode 100644 index 0000000..a42f3da --- /dev/null +++ b/database_tables/hvac_minimum_requirement_water_heaters_IECC.py @@ -0,0 +1,15 @@ +import sqlite3 + +from database_tables.hvac_minimum_requirement_water_heaters import ( + HVACMinimumRequirementWaterHeaters, +) + +TABLE_NAME = "hvac_minimum_requirement_water_heaters_IECC" + + +class HVACMinimumRequirementWaterHeatersIECCTable(HVACMinimumRequirementWaterHeaters): + def __init__(self): + super(HVACMinimumRequirementWaterHeatersIECCTable, self).__init__( + table_name=TABLE_NAME, + initial_data_directory=f"database_files/{TABLE_NAME}", + )