Skip to content

Latest commit

 

History

History
272 lines (173 loc) · 8.57 KB

yrd220_0_0.md

File metadata and controls

272 lines (173 loc) · 8.57 KB
layout title
documentation
YRD220 - ZWave

{% include base.html %}

YRD220 Yale Real Living Touchscreen Deadbolt

This describes the Z-Wave device YRD220, manufactured by ASSA ABLOY with the thing type UID of yale_yrd220_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

YRD220 product image

The YRD220 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The Yale Real Living Stand-alone Touchscreen Deadbolt Lock combines a robust lockset with a contemporary aesthetic.

Inclusion Information

To include the lock in a Z-Wave Network (taken from the installation manual:

  1. Touch the lock screen to activate
  2. Enter the master pin and press #
  3. Press 7, then #
  4. Press 1, then #

The lock will now be in inclusion mode.

Exclusion Information

To exclude the lock from a Z-Wave Network (taken from the installation manual:

  1. Touch the lock screen to activate
  2. Enter the master pin and press #
  3. Press 7, then #
  4. Press 3, then #

The lock will now be in exclusion mode.

Channels

The following table summarises the channels available for the YRD220 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm alarm_general alarm_general Alarm Switch
Alarm Raw alarm_raw alarm_raw String
Battery Level battery-level system.battery_level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm Raw

Provides alarm parameters as json string.

The alarm_raw channel is of type alarm_raw and supports the String item. This is a read only channel so will only be updated following state changes from the device. This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the YRD220. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Audio Volume Sets the volume level of the beeps and voice prompts
2 Auto Re-lock When enabled, the unit will automatically re-lock
3 Re-lock Time Time after unlocking that the device will lock
4 Wrong Code Entry Limit The number of invalid tries before the lock shutdowns and sends an alarm
5 Language Language used by the voice prompts
7 Shutdown Time Number of times the device is locked out after the invalid retries are exceeded
8 Operating Mode Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock
Lock Timeout Sets the time after which the door will auto lock

Parameter 1: Audio Volume

Sets the volume level of the beeps and voice prompts 1 = Silent

2 = Low

3 = High The following option values may be configured -:

Value Description
1 Silent
2 Low
3 High

The manufacturer defined default value is 3 (High).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Auto Re-lock

When enabled, the unit will automatically re-lock 0 = Off

255 = On The following option values may be configured -:

Value Description
0 Off
255 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Re-lock Time

Time after unlocking that the device will lock

Values in the range 5 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Wrong Code Entry Limit

The number of invalid tries before the lock shutdowns and sends an alarm

Values in the range 1 to 7 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Language

Language used by the voice prompts 1 = English

2 = Spanish

3 = French The following option values may be configured -:

Value Description
1 English
2 Spanish
3 French

The manufacturer defined default value is 1 (English).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: Shutdown Time

Number of times the device is locked out after the invalid retries are exceeded

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Operating Mode

Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock 0 = Normal

1 = Vacation Mode (User Codes Disabled)

2 = Privacy Mode (User Codes and ZWave Codes Disabled The following option values may be configured -:

Value Description
0 Normal
1 Vacation Mode
2 Privacy Mode

The manufacturer defined default value is 0 (Normal).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The YRD220 supports 1 association group.

Group 1: Alarm Reports

Alarm reports are sent out to all devices in the association group

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_LOCK_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_TIME_V1
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.