DRY Widom Smart Dry contact

This describes the Z-Wave device DRY, manufactured by wiDom with the thing type UID of widom_dry_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

DRY product image

The DRY supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

WiDom Smart Dry Contact Switch can turn ON and OFF equipments with an independent power supply, such as solenoid valves (e.g. gas, water and irrigation), power operated valves etc. 

WiDom Smart Dry Contact Switch is very easy to install and works with both momentary and toggle switches. 

The device is equipped with contact protection technology (Zero Crossing) which reduces the electrical stress on the relay contacts and ensures a longer life. The open / closed switching of the device always occur when the instantaneous value of voltage is 0. 

It operates in any Z-Wave network with other Z-Wave/Z-Wave Plus certified devices and controllers from any other manufacturer. As a constantly powered node, WiDom Smart Double Switch will act as repeater regardless of the vendor in order to increase the reliability of the network.

Inclusion Information

WiDom Smart Dry Contact Switch is compatible with all Z-Wave/Z-Wave Plus certified controllers. The device supports both the Network Wide Inclusion mechanism (which offers the ability to be included in a network, even if the device is not directly connected to the controller) and Normal Inclusion. By default, the inclusion procedure starts in Normal Inclusion mode and after a short time out the procedure continues in Network Wide Inclusion mode that lasts for about 20 Seconds.

Before including the device the LED status indicator is solid RED. The procedure of inclusion is activated by clicking Add in the inclusion interface and by pressing any sequence of click on the integrated button. As soon as the inclusion procedure initiates the LED indicator starts a sequence of GREEN-BLUE blinks. The device is included in the network when the LED status is OFF and the interview is completed. 

Exclusion Information

Only a controller can remove the device from the network. After activating the exclusion function by the controller, the device can be removed by setting it in Learning Mode. As soon as the exclusion initiates, the LED indicator starts a sequence of RED-BLUE blinks. The device is excluded from the network when the LED status indicator is solid RED and the App_status in the interface is OK. 

Channels

The following table summarises the channels available for the DRY -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the DRY. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Numbers of clicks to control the load Defines which sequences of clicks control the load
4 Value used for devices belonging to Group 2 Value sent when the external switch receives 1 Click
5 Value used for devices belonging to Group 3 Value sent wen the external switch receives 2 Clicks
6 Value used for devices belonging to Group 4 Value sent when external switch receives 3 Clicks
10 Timer to switch OFF the Relay Defines the time after which the relay is switched OFF
11 Timer to switch ON the Relay Defines the time after which the relay is switched ON
15 Timer scale Defines the time unit used for parameters No.10 and No.11.
20 One Click Scene Activation Set Defines the Scene Activation Set value sent to the Lifeline group with 1 Click
21 Two Clicks Scene Activation Set Defines the Scene Activation Set value sent to the Lifeline group with 2 Clicks
22 Three Clicks Scene Activation Set Defines the Scene Activation Set value sent to the Lifeline group with 3 Clicks
60 Start-up Status Defines the status of the device following a restart
62 Type of external switch Defines the type of external switch connected to the device

Parameter 1: Numbers of clicks to control the load

Defines which sequences of clicks control the load

Values in the range 0 to 7 may be set.

The manufacturer defined default value is 7.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 4: Value used for devices belonging to Group 2

Value sent when the external switch receives 1 Click

Values in the range -1 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Value used for devices belonging to Group 3

Value sent wen the external switch receives 2 Clicks  Value used for devices belonging to Group 3 when the external switch receives 2 Clicks Values in the range -1 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Value used for devices belonging to Group 4

Value sent when external switch receives 3 Clicks  Value used for devices belonging to Group 4 when external switch receives 3 Clicks Values in the range -1 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 10: Timer to switch OFF the Relay

Defines the time after which the relay is switched OFF

Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Timer to switch ON the Relay

Defines the time after which the relay is switched ON

Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 15: Timer scale

Defines the time unit used for parameters No.10 and No.11.

Values in the range 1 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_15_2_wo and is of type INTEGER. This is a write only parameter.

Parameter 20: One Click Scene Activation Set

Defines the Scene Activation Set value sent to the Lifeline group with 1 Click Defines the Scene Activation Set value sent to the Lifeline group with 1 Click on the external switch Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_2 and is of type INTEGER.

Parameter 21: Two Clicks Scene Activation Set

Defines the Scene Activation Set value sent to the Lifeline group with 2 Clicks Defines the Scene Activation Set value sent to the Lifeline group with 2 Clicks on the external switch Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_2 and is of type INTEGER.

Parameter 22: Three Clicks Scene Activation Set

Defines the Scene Activation Set value sent to the Lifeline group with 3 Clicks Defines the Scene Activation Set value sent to the Lifeline group with 3 Clicks on the external switch Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_22_2 and is of type INTEGER.

Parameter 60: Start-up Status

Defines the status of the device following a restart

The following option values may be configured -:

Value Description
1 On
2 Off
3 PREVIOUS STATUS

The manufacturer defined default value is 3 (PREVIOUS STATUS).

This parameter has the configuration ID config_60_1 and is of type INTEGER.

Parameter 62: Type of external switch

Defines the type of external switch connected to the device

The following option values may be configured -:

Value Description
0 IGNORE
1 BUTTON
2 SWITCH

The manufacturer defined default value is 1 (BUTTON).

This parameter has the configuration ID config_62_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The DRY supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 8 nodes.

Group 2: 1 Click

Association group 2 supports 8 nodes.

Group 3: 2 Clicks

Association group 3 supports 8 nodes.

Group 4: 3 Clicks

Association group 4 supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1
COMMAND_CLASS_SECURITY_V1