layout title
documentation
ZV9002T4-CCT - ZWave

{% include base.html %}

ZV9002T4-CCT 4 group CCT touch panel secondary controller

This describes the Z-Wave device ZV9002T4-CCT, manufactured by Sunricher with the thing type UID of sunricher_zv9002t4_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZV9002T4-CCT product image

The ZV9002T4-CCT supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

SR-ZV9002T4-CCT-EU is a touch control Z-Wave Plus certified wall controller for dual color LED Lighting. As a z-wave secondary controller,
it is a z wave light switch which can be added to z-wave network and removed from z-wave network by z-wave primary (master) controllers
or gateway and control z-wave devices that are added to the network It supports 5 groups for associations, a lifeline group association to
primary (master) controller and 4 groups association to devices, the group association to devices supports maximum 12 Z-wave devices per group.

It is a universal z-wave slave which can be compatible with universal z-wave primary controller or gateway. The wireless controller is compatible with dual color z wave device SR-ZV9102FA-CCT and different frequencies are available for different countries or areas. The signal transmit distance can be up to 30m. The controller supports group and scene storage and recall functions.

The controller is easy to install on the wall and available in standard EU size.

Key Features

  • Z-Wave Plus certified
  • Touch panel dual color Z-Wave wall controller
  • Source-routed Mesh Network Architecture
  • Each device works as a node
  • All Nodes Are Transceivers
  • Each Z-wave Network Allows Up to 232 Devices
  • Actively route around and circumvent obstacles or radio dead spots
  • Wireless Synchronization to Drastically Increase Control Distance
  • Devices can communicate to one another by using intermediate nodes
  • Added or removed by primary controllers or gateway
  • Supports 1 lifeline group association to master controller
  • Supports 4 groups association to z-wave devices, maximum 12 devices per group
  • Compatible with universal z-wave primary controller or gateway
  • Supports group, scene storage and recall functions

Inclusion Information

Inclusion (Add the device to a Z-Wave network):

  1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).
  2. Make sure the wall controller does not belong to any Z-Wave network (please refer to the part “How to check whether the wall controller included to a network” of this manual).
  3. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion.

Once the wall controller quits “inclusion mode”, the LED indicator will turns off. There are 3 methods for the wall controller to quit “inclusion mode”:

  1. Automatically quits after successful inclusion.
  2. Quits after 25 seconds timeout.
  3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the “inclusion/exclusion” button to quit.

Exclusion Information

Exclusion (Remove the device from a Z-Wave network) There are two exclusion methods:

Method 1: Exclusion from the primary controller/gateway as follows:

  1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
  2. Short press the “inclusion/exclusion” button, or press and hold down “ALL ON/OFF” button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful exclusion.

Once the wall controller quits “exclusion mode”, the LED indicator will turns off. There are 3 methods for the wall controller to quit “exclusion mode”:

  1. Automatically quits after successful exclusion.
  2. Quits after 25 seconds timeout.
  3. Press and hold down “ALL ON/OFF” button for over 3 seconds, or short press the “inclusion/exclusion” button to quit.

Method 2: Factory reset the wall controller will force the wall controller to be excluded from a network. (please refer to the part “Factory Reset” of this manual)Note:

Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.

How to check whether the wall controller already included to a network
Operate any button to check if there is indication from the LED indicator, and no LED indication means the wall controller does not belong to any network. If the wall controller already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device will fail.

Factory Reset
Press and hold down “inclusion/exclusion” button for over 8 seconds, LED indicator will blink slowly to indicate successful factory reset, release “inclusion/exclusion” button, the wall controller will restart automatically. If this controller is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary after the reset to exclude and re-include all of the nodes in the network. If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable.

Channels

The following table summarises the channels available for the ZV9002T4-CCT -:

Channel Name Channel ID Channel Type Category Item Type
Scene Number scene_number scene_number Number

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZV9002T4-CCT supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

  1. Send “Command Class Device Reset Locally” to associated devices of this group to report factory reset information when factory reset the wall controller.
  2. Double click a group number of the wall controller to send command to associated devices of this group using “Command Class Central Scene”.

Association group 1 supports 1 node.

Group 2: Launch 1

  1. Press and hold down button "1" to activate group in order to switch the associated devices with a Basic Set or dim these devices by using the two brightness buttons or adjust color temperature by using color wheel.
  2. Short press Scene button S1/S2/S3/S4, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
  3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

Association group 2 supports 12 nodes.

Group 3: Launch 2

  1. Press and hold down button "2" to activate group in order to switch the associated devices with a Basic Set or dim these devices by using the two brightness buttons or adjust color temperature by using color wheel.
  2. Short press Scene button S1/S2/S3/S4, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
  3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

Association group 3 supports 12 nodes.

Group 4: Launch 3

  1. Press and hold down button "3" to activate group in order to switch the associated devices with a Basic Set or dim these devices by using the two brightness buttons or adjust color temperature by using color wheel.
  2. Short press Scene button S1/S2/S3/S4, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
  3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

Association group 4 supports 12 nodes.

Group 5: Launch 4

  1. Press and hold down button "4" to activate group in order to switch the associated devices with a Basic Set or dim these devices by using the two brightness buttons or adjust color temperature by using color wheel.
  2. Short press Scene button S1/S2/S3/S4, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
  3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

Association group 5 supports 12 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.