009501 Popp 09501 Flow Stop

This describes the Z-Wave device 009501, manufactured by Popp & Co with the thing type UID of popp_009501_01_001. This version of the device is limited to firmware versions 1.1 to 1.2

The device is in the category of Valve, defining Valves used to control water or gas. e.g. a flow stop valve..

009501 product image

The 009501 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The Flow Stop moves the operating handle of a ball valve allowing to stopping the flow of gas or water. It can be mounted non-intrusive on any pipe size between 0.5 and 1.5 inch. This means the original water or gas pipe will not be opened or manipulated and it is possible to remove the Flow stop again without any damage to the water or gas pipe. Installing the Flow stop will not tamper or change any security measure applied or your gas or water installation.

The device is equipped with a powerful 12 V motor providing sufficient torque to open or close any ball valve within 10 seconds. A complete manual operation of the valve remains possible due to the clutch release bearing.

Inclusion Information

For inclusion press the red button on the top of the enclosure 3 times

Exclusion Information

For exclusion press the red button on the top of the enclosure 3 times

Wakeup Information

The 009501 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the 009501 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the 009501. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 LED Status No help available, self explanatory....
1 Shut-off controller behavior The parameter defines how to control the shut-off controller.

Parameter 0: LED Status

No help available, self explanatory.... 0: LED always ON (Only on operation OFF)
1: LED always OFF (Only on operation ON) Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: Shut-off controller behavior

The parameter defines how to control the shut-off controller. 0: Remote and manually open/close
1: Remote open/close only
2: Only remote open; only manually closing
3: Only manually open; only remote closing
4: Manually open/close only Values in the range 0 to 4 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 009501 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 10 nodes.

Group 2: Local Valve Operation

Association group 2 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2