Skip to content

Latest commit

 

History

History
156 lines (100 loc) · 7.17 KB

psm08_0_0.md

File metadata and controls

156 lines (100 loc) · 7.17 KB
layout title
documentation
PSM08 - ZWave

{% include base.html %}

PSM08 Door/Window Sensor

This describes the Z-Wave device PSM08, manufactured by Philio Technology Corp with the thing type UID of philio_psm08_00_000.

The device is in the category of Door, defining Door sensors.

PSM08 product image

The PSM08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The PSM08 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The door/window sensor PSM08 has door/window sensor function, based on Z-WaveTM technology.This device is a Security Enabled Z-Wave Plus Product.

Inclusion Information

  1.  Have Z-WaveTM Controller entered inclusion mode.
  2.  Pressing button once to enter the inclusion mode.
  3.  After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.

Exclusion Information

  1.  Have Z-WaveTM Controller entered exclusion mode.
  2.  Pressing button once to enter the exclusion mode. Node ID has been excluded

Wakeup Information

The PSM08 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 12 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please remove the front cover, and press the button once. The device will wake-up 10 seconds.

Channels

The following table summarises the channels available for the PSM08 -:

Channel Name Channel ID Channel Type Category Item Type
Alarm (access) alarm_access alarm_access Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Door Sensor sensor_door sensor_door Door Contact
Tamper Alarm alarm_tamper alarm_tamper Switch
Battery Level battery-level system.battery_level Battery Number

Alarm (access)

Indicates if the access control alarm is triggered.

The alarm_access channel is of type alarm_access and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Door Sensor

Indicates if the door/window is open or closed.

The sensor_door channel is of type sensor_door and supports the Contact item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Contact item type -:

Value Label
OPEN Open
CLOSED Closed

Tamper Alarm

Indicates if the tamper alarm is triggered.

The alarm_tamper channel is of type alarm_tamper and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PSM08 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links