Skip to content

Latest commit

 

History

History
221 lines (133 loc) · 7.73 KB

45606_0_0.md

File metadata and controls

221 lines (133 loc) · 7.73 KB
layout title
documentation
45606, ZW3003 - ZWave

{% include base.html %}

45606, ZW3003 2-Way Dimmer Switch

This describes the Z-Wave device 45606, ZW3003, manufactured by Jasco Products with the thing type UID of ge_45606_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

45606, ZW3003 product image

The 45606, ZW3003 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Wireless Lighting Control, On/Off/Dim Dimmer Switch

Inclusion Information

Tap the top or bottom of the rocker

Exclusion Information

Tap the top or bottom of the rocker

Channels

The following table summarises the channels available for the 45606, ZW3003 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the 45606, ZW3003. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Defines the behavior of the blue LED.
4 Invert Switch Change the top of the switch to OFF and the bottom of the switch to ON.
5 Ignore Start-Level (Receiving) This dimmer will start dimming from its current level.
7 On/Off Command Dim Step Indicates how many levels the dimmer will change for each dimming step.
8 On/Off Command Dim Rate Sets the rate at which the dimmer changes the light level.
9 Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step.
10 Local Control Dim Rate Sets the dim rate
11 ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step.
12 ALL ON/ALL OFF Dim Rate Sets the dim rate for the all on/off command
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off. The following option values may be configured -:

Value Description
0 LED on when switch is OFF
1 LED on when switch is ON
2 LED always off

The manufacturer defined default value is 0 (LED on when switch is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Ignore Start-Level (Receiving)

This dimmer will start dimming from its current level.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: On/Off Command Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: On/Off Command Dim Rate

Sets the rate at which the dimmer changes the light level. This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Local Control Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Local Control Dim Rate

Sets the dim rate This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dimmer will change. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: ALL ON/ALL OFF Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ALL ON/ALL OFF Dim Rate

Sets the dim rate for the all on/off command This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dimmer will change. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.