GE/Jasco 14285 - ZWave

{% include base.html %}

GE/Jasco 14285 Direct Wire Indoor/Outdoor Smart Switch

This describes the Z-Wave device GE/Jasco 14285, manufactured by Jasco Products with the thing type UID of ge_14285_00_000.

The device is in the category of Remote Control, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc..

GE/Jasco 14285 product image

The GE/Jasco 14285 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

SPECIFICATIONS ZW4007

  • Power: 120-277 VAC, 60Hz, Single Phase
  • Range: Up to 150 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
  • Operating Temperature Range: -22 to 104° F (-30 to 40° C)
  • For outdoor use in dry, damp or wet locations.
  • Contact Ratings: 120-277 VAC, 40A Resistive Single Phase 120-277 VAC, 20A Ballast load (Inductive) Single phase 125 VAC, 15 A Tungsten 250 VAC, 5 A Tungsten 1HP@120VAC, 2HP @ 240VAC

Features

  • Operation mode switch allows operation without requiring Z-Wave network
  • Remote ON/OFF control via the Z-Wave controller, on mobile devices
  • Manual override ON/OFF control with the exterior-mounted pushbutton
  • Weather-resistant, rainproof housing; suitable for use outdoors in damp or wet conditions
  • Lockable tamper-resistant metal case ensures secure connection and keeps dirt & debris out
  • Energy monitoring capability allows remote monitoring of watts and kilowatt hours with compatible systems 

Device Reset

To return your device to factory defaults

  1. Place device into ON mode (upper position of Operating Mode Switch)
  2. Press and hold the programming button.
  3. While holding programming button, place device into OFF mode (middle position of Operating Mode Switch).
  4. While holding programming button, place device back into ON mode (upper position of Operating Mode Switch).
  5. After three (3) seconds, release programming button. Green LED will flash 5 times when completed successfully.

Inclusion Information

Once the controller is ready to add your device, press and release the programming button to add it to the network. 

Exclusion Information

Once the controller is ready to remove your device press and release the programming button to remove it from the network.

Channels

The following table summarises the channels available for the GE/Jasco 14285 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Scene Number scene_number scene_number Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the GE/Jasco 14285. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Product State after Power Reset Product State after Power Reset
2 Energy Report Mode Energy Report Mode
3 Energy Report Frequency Energy Report Frequency
19 Alternate Exclusion Alternate Exclusion

Parameter 1: Product State after Power Reset

Product State after Power Reset

The following option values may be configured -:

Value Description
0 Return to last state
1 Return to off
2 Return to on

The manufacturer defined default value is 0 (Return to last state).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Energy Report Mode

Energy Report Mode

The following option values may be configured -:

Value Description
0 Once monthly
1 Reports based on Parameter 3 setting
2 Once daily

The manufacturer defined default value is 0 (Once monthly).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Energy Report Frequency

Energy Report Frequency

Values in the range 5 to 60 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 19: Alternate Exclusion

Alternate Exclusion This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Default
1 Alternate Exclusion (3 button presses)

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE/Jasco 14285 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Basic Set, controlled by local load

Association group 2 supports 5 nodes.

Group 3: Basic Set,

controlled by pressing the On or Off button Basic Set, controlled by pressing the On or Off button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links