layout | title |
---|---|
documentation |
GE/Jasco 14285 - ZWave |
{% include base.html %}
This describes the Z-Wave device GE/Jasco 14285, manufactured by Jasco Products with the thing type UID of ge_14285_00_000
.
The device is in the category of Remote Control, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc..
The GE/Jasco 14285 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
SPECIFICATIONS ZW4007
- Power: 120-277 VAC, 60Hz, Single Phase
- Range: Up to 150 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
- Operating Temperature Range: -22 to 104° F (-30 to 40° C)
- For outdoor use in dry, damp or wet locations.
- Contact Ratings: 120-277 VAC, 40A Resistive Single Phase 120-277 VAC, 20A Ballast load (Inductive) Single phase 125 VAC, 15 A Tungsten 250 VAC, 5 A Tungsten 1HP@120VAC, 2HP @ 240VAC
Features
- Operation mode switch allows operation without requiring Z-Wave network
- Remote ON/OFF control via the Z-Wave controller, on mobile devices
- Manual override ON/OFF control with the exterior-mounted pushbutton
- Weather-resistant, rainproof housing; suitable for use outdoors in damp or wet conditions
- Lockable tamper-resistant metal case ensures secure connection and keeps dirt & debris out
- Energy monitoring capability allows remote monitoring of watts and kilowatt hours with compatible systems
Device Reset
To return your device to factory defaults
- Place device into ON mode (upper position of Operating Mode Switch)
- Press and hold the programming button.
- While holding programming button, place device into OFF mode (middle position of Operating Mode Switch).
- While holding programming button, place device back into ON mode (upper position of Operating Mode Switch).
- After three (3) seconds, release programming button. Green LED will flash 5 times when completed successfully.
Once the controller is ready to add your device, press and release the programming button to add it to the network.
Once the controller is ready to remove your device press and release the programming button to remove it from the network.
The following table summarises the channels available for the GE/Jasco 14285 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Scene Number | scene_number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
The following table provides a summary of the 4 configuration parameters available in the GE/Jasco 14285. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Product State after Power Reset | Product State after Power Reset |
2 | Energy Report Mode | Energy Report Mode |
3 | Energy Report Frequency | Energy Report Frequency |
19 | Alternate Exclusion | Alternate Exclusion |
Product State after Power Reset
The following option values may be configured -:
Value | Description |
---|---|
0 | Return to last state |
1 | Return to off |
2 | Return to on |
The manufacturer defined default value is 0
(Return to last state).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Energy Report Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Once monthly |
1 | Reports based on Parameter 3 setting |
2 | Once daily |
The manufacturer defined default value is 0
(Once monthly).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Energy Report Frequency
Values in the range 5 to 60 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Alternate Exclusion This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
1 | Alternate Exclusion (3 button presses) |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE/Jasco 14285 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
controlled by pressing the On or Off button Basic Set, controlled by pressing the On or Off button
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.