HCL: Digitus DN-170093 supported by nutdrv_qx 2.8.2 #2770
Labels
DDL
impacts-release-2.8.2
Issues reported against NUT release 2.8.2 (maybe vanilla or with minor packaging tweaks)
Qx protocol driver
Driver based on Megatec Q<number> such as new nutdrv_qx, or obsoleted blazer and some others
Manufacturer : Digitus
Part number : DN-170093
Device manufacturer and name,
Output:
Config:
[UPS]
driver = "nutdrv_qx"
protocol = "megatec"
port = "auto"
desc = "Digitus 1000VA UPS"
vendorid = "0001"
productid = "0000"
default.battery.voltage.high = 27.43
default.battery.voltage.low = 20.81
override.battery.voltage.nominal = 24.00
override.battery.packs = 12
battery_voltage_reports_one_pack
runtimecal = 210,100,1985,20
chargetime = 15000
idleload = 9
I have tested the shutdown sequence.
Link:
https://de.assmann.shop/en/IT-Infrastructure/Uninterruptible-Power-Supply-UPS/Server-and-Network/OnLine-UPS-system-1000-VA-1000-W.html?listtype=search#&gid=1&pid=3
This only works with version 2.8.2 - 2.8.1 reports incorrect battery voltage & charge does not work.