Hi! Could? Possibly (without really knowing the actual requirements). Cheers! |
Hi, we use a EPEVER IP Plus 2000 22 (24 Volt) pure sine wave inverter. The inverter has a potential-free contact to turn it on. The fridge thermostat is already disassembled. Power efficient solution is to not run the inverter all the time in standby ~ 15 W @ 230 V Cheers! |
Ok.Well, if that is the case, I guess it might make sense. That is, it could be do-able. Cheers! |
https://www.amazon.de/gp/product/B07RD9DRXZ/ref=ppx_yo_dt_b_asin_title_o00_s00?ie=UTF8&psc=1 Bought the 24 Volt version.
How the hell is that supposed to work ? |
Ok, first off, not all STC-1000's are equal. There have been numerous different 'clones' spotted, all using varying microcontrollers (they look similar from the outside though), so it depends on what actual hardware you got if it can even be reflashed. Secondly, that fridge thermostat you pictured can most likely be thought of as a temperature actuated mains switch, it probably just sits in series with the mains connection to the compressor, closing the switch (turning on the compressor) when temperature in the fridge rises. It would be potential free if you disconnect the spade connectors from it... Note that these thermostats are mechanical devices, the do not need mains power to function, they actuate by the change in pressure of a contained gas due to change in temperature. Here's more info: My suggestion is, that you disconnect mains in and mains out from the thermostat, short those two leads together (making the compressor always run) and connect the 'potential free contact' on the inverter to the thermostat instead. Cheers! |
yes of course
The inverter is also for other electricity consumer ... if no one is there, the inverter is switched off ... and will be avtivated by the potential-free contact ... the other electricity consumer are disconnected then ...
Well sounds not much easier to me. |
See, you didn't mention that before :)
Easier than what? Modifying the firmware of a thermostat that may not even be modifiable? Cheers! |
Hi,
would it be possible to write a firmware that uses the heating output to switch on a 230V inverter?
A delay element, which switches on the inverter a few seconds before the compressor, would be very nice.
best regards
Marcus