Skip to content

Latest commit

 

History

History
723 lines (534 loc) · 69.5 KB

SUPPORTED_PROFILES.md

File metadata and controls

723 lines (534 loc) · 69.5 KB

Supported profiles

All profiles (should) correspond to the official EEP by EnOcean.

RPS Telegram (0xF6)

RORG 0xF6 - FUNC 0x01 - TYPE 0x01 - Push Button
shortcut description type values
PB Status of the push button enum 0 - Released
1 - Pressed
RORG 0xF6 - FUNC 0x02 - TYPE 0x01 - Light and Blind Control - Application Style 1
shortcut description type values
R1 Rocker 1st action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
EB Energy bow enum 0 - released
1 - pressed
R2 Rocker 2nd action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
SA 2nd action enum 0 - No 2nd action
1 - 2nd action valid
T21 T21 status
NU NU status
RORG 0xF6 - FUNC 0x02 - TYPE 0x02 - Light and Blind Control - Application Style 2
shortcut description type values
R1 Rocker 1st action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
EB Energy bow enum 0 - released
1 - pressed
R2 Rocker 2nd action enum 0 - Button AI
1 - Button AO
2 - Button BI
3 - Button BO
SA 2nd action enum 0 - No 2nd action
1 - 2nd action valid
T21 T21 status
NU NU status
RORG 0xF6 - FUNC 0x05 - TYPE 0x01 - Liquid Leakage Sensor (mechanic harvester)
shortcut description type values
WAS Water Sensor enum 0-16 - not specified
17 - Water detected
18-255 - not specified
T21 T21 status
NU NU status
RORG 0xF6 - FUNC 0x05 - TYPE 0x02 - Smoke Detector
shortcut description type values
SMO Status of detection and battery enum 0 - Smoke Alarm OFF
16 - Smoke Alarm ON
48 - Energy LOW
RORG 0xF6 - FUNC 0x10 - TYPE 0x00 - Window Handle
shortcut description type values
WIN Window handle enum 0 - Moved from up to vertical
1 - Moved from vertical to up
2 - Moved from down to vertical
3 - Moved from vertical to down
T21 T21 status
NU NU status

1BS Telegram (0xD5)

RORG 0xD5 - FUNC 0x00 - TYPE 0x01 - Single Input Contact
shortcut description type values
CO Contact enum 0 - open
1 - closed

4BS Telegram (0xA5)

RORG 0xA5 - FUNC 0x02 - TYPE 0x01 - Temperature Sensor Range -40°C to 0°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -40.0-0.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x02 - Temperature Sensor Range -30°C to +10°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -30.0-10.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x03 - Temperature Sensor Range -20°C to +20°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -20.0-20.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x04 - Temperature Sensor Range -10°C to +30°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -10.0-30.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x05 - Temperature Sensor Range 0°C to +40°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x06 - Temperature Sensor Range +10°C to +50°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 10.0-50.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x07 - Temperature Sensor Range +20°C to +60°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 20.0-60.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x08 - Temperature Sensor Range +30°C to +70°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 30.0-70.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x09 - Temperature Sensor Range +40°C to +80°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 40.0-80.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x0A - Temperature Sensor Range +50°C to +90°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 50.0-90.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x0B - Temperature Sensor Range +60°C to +100°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 60.0-100.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x10 - Temperature Sensor Range -60°C to +20°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -60.0-20.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x11 - Temperature Sensor Range -50°C to +30°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -50.0-30.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x12 - Temperature Sensor Range -40°C to +40°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -40.0-40.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x13 - Temperature Sensor Range -30°C to +50°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -30.0-50.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x14 - Temperature Sensor Range -20°C to +60°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -20.0-60.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x15 - Temperature Sensor Range -10°C to +70°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ -10.0-70.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x16 - Temperature Sensor Range 0°C to +80°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-80.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x17 - Temperature Sensor Range +10°C to +90°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 10.0-90.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x18 - Temperature Sensor Range +20°C to +100°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 20.0-100.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x19 - Temperature Sensor Range +30°C to +110°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 30.0-110.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x1A - Temperature Sensor Range +40°C to +120°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 40.0-120.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x1B - Temperature Sensor Range +50°C to +130°C
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 50.0-130.0 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x20 - 10 Bit Temperature Sensor Range -10°C to +41.2°C
shortcut description type values
TMP Temperature (linear) value 1023.0-0.0 ↔ -10.0-41.2 °C
RORG 0xA5 - FUNC 0x02 - TYPE 0x30 - 10 Bit Temperature Sensor Range -40°C to +62.3°C
shortcut description type values
TMP Temperature (linear) value 1023.0-0.0 ↔ -40.0-62.3 °C
RORG 0xA5 - FUNC 0x04 - TYPE 0x01 - Range 0°C to +40°C and 0% to 100%
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C
TSN Availability of the Temperature Sensor enum 0 - not available
1 - available
RORG 0xA5 - FUNC 0x04 - TYPE 0x03 - Range -20°C to +60°C 10bit-measurement and 0% to 100%
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-255.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-1023.0 ↔ -20.0-60.0 °C
TTP Telegram Type enum 0 - Heartbeat
1 - Event triggered
RORG 0xA5 - FUNC 0x06 - TYPE 0x01 - Range 300lx to 60.000lx
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL2 Illumination 2 (linear) value 0.0-255.0 ↔ 300.0-30000.0 lx
ILL1 Illumination 1 (linear) value 0.0-255.0 ↔ 600.0-60000.0 lx
RS Range select enum 0 - Range acc. to DB_1 (ILL1)
1 - Range acc. to DB_2 (ILL2)
RORG 0xA5 - FUNC 0x06 - TYPE 0x02 - Range 0lx to 1.020lx
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL2 Illumination 2 (linear) value 0.0-255.0 ↔ 0.0-510.0 lx
ILL1 Illumination 1 (linear) value 0.0-255.0 ↔ 0.0-1020.0 lx
RS Range select enum 0 - Range acc. to DB_1 (ILL1)
1 - Range acc. to DB_2 (ILL2)
RORG 0xA5 - FUNC 0x07 - TYPE 0x01 - Occupancy with Supply voltage monitor
shortcut description type values
SVC Supply voltage (OPTIONAL) value 0.0-250.0 ↔ 0.0-5.0 V
PIR PIR Status enum 0 - off
1 - on
RORG 0xA5 - FUNC 0x08 - TYPE 0x01 - Range 0lx to 510lx, 0°C to +51°C and Occupancy Button
shortcut description type values
SVC Supply voltage (linear) value 0.0-255.0 ↔ 0.0-5.1 V
ILL Illumination (linear) value 0.0-255.0 ↔ 0.0-510.0 lx
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C
PIRS PIR Status enum 0 - PIR on
1 - PIR off
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
RORG 0xA5 - FUNC 0x09 - TYPE 0x04 - CO2 Sensor
shortcut description type values
HUM Rel. Humidity (linear) value 0.0-200.0 ↔ 0.0-100.0 %
Conc Concentration (linear) value 0.0-255.0 ↔ 0.0-2550.0 ppm
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-51.0 °C
RORG 0xA5 - FUNC 0x09 - TYPE 0x05 - VOC Sensor
shortcut description type values
Conc VOC Concentration value 0.0-65535.0 ↔ 0.0-65535.0 ppb
VOC_ID VOC Identification enum 0 - VOCT (total)
1 - Formaldehyde
2 - Benzene
3 - Styrene
4 - Toluene
5 - Tetrachloroethylene
6 - Xylene
7 - n-Hexane
8 - n-Octane
9 - Cyclopentane
10 - Methanol
11 - Ethanol
12 - 1-Pentanol
13 - Acetone
14 - ethylene Oxide
15 - Acetaldehyde ue
16 - Acetic Acid
17 - Propionice Acid
18 - ValericAcid
19 - ButyricAcid
20 - Ammoniac
22 - Hydrogen Sulfide
23 - Dimethylsulfide
24 - 2-Butanol (butyl Alcohol)
25 - 2-Methylpropanol
26 - Diethyl ether
255 - ozone
RORG 0xA5 - FUNC 0x10 - TYPE 0x03 - Temperature Sensor and Set Point
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 %
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
RORG 0xA5 - FUNC 0x10 - TYPE 0x05 - Temperature Sensor, Set Point and Occupancy Control
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 %
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
RORG 0xA5 - FUNC 0x10 - TYPE 0x06 - Temperature Sensor, Set Point and Day/Night Control
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0 %
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
SLSW Slide switch enum 0 - Position I / Night / Off
1 - Position O / Day / On
RORG 0xA5 - FUNC 0x10 - TYPE 0x10 - Temperature and Humidity Sensor, Set Point and Occupancy Control
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C
OCC Occupancy Button enum 0 - Button pressed
1 - Button released
RORG 0xA5 - FUNC 0x10 - TYPE 0x12 - Temperature and Humidity Sensor and Set Point
shortcut description type values
SP Set Point (linear) value 0.0-255.0 ↔ 0.0-255.0
HUM Rel. Humidity (linear) value 0.0-250.0 ↔ 0.0-100.0 %
TMP Temperature (linear) value 0.0-250.0 ↔ 0.0-40.0 °C
RORG 0xA5 - FUNC 0x11 - TYPE 0x02 - Temperature Controller Output
shortcut description type values
CVAR Actual value of controller value 0.0-255.0 ↔ 0.0-100.0 %
FAN Actual value of fan enum 0 - State 0 Manual
1 - State 1 Manual
2 - State 2 Manual
3 - State 3 Manual
16 - State 0 Automatic
17 - State 1 Automatic
18 - State 2 Automatic
19 - State 3 Automatic
255 - Not Available
ASP Actual Setpoint value 0.0-255.0 ↔ 0.0-51.2 C
ALR Alarm enum 0 - No alarm
1 - Alarm
CTM Controller mode enum 1 - Heating
2 - Cooling
3 - Off
CTS Controller state enum 0 - Automatic
1 - Override
ERH Energy hold-off enum 0 - Normal
1 - Energy hold-off / Dew point
RO Room occupancy enum 0 - Occupied
1 - Unoccupied
2 - StandBy
3 - Frost
RORG 0xA5 - FUNC 0x11 - TYPE 0x03 - Blind Status
shortcut description type values
BSP Blind/shutter position value 0.0-100.0 ↔ 0.0-100.0 %
AS Angle sign enum 0 - Positive sign
1 - Negative sign
AN Angle in 2 degrees steps value 0.0-90.0 ↔ 0.0-180.0 degrees
PVF Position value flag enum 0 - No position value available
1 - Position value available
AVF Angle value flag enum 0 - No Angle value available
1 - Angle value available
ES Error state enum 0 - No error present
1 - End-positions are not configured
2 - Internal failure
3 - Not used
EP End position enum 0 - No End-position available
1 - No End-position reached
2 - Blind fully open
3 - Blind fully closed
ST Status enum 0 - No status available
1 - Blind is stopped
2 - Blind opens
3 - Blind closes
SM Service mode enum 0 - Normal mode
1 - Service mode activated
MOTP Mode of the position enum 0 - Normal mode
1 - Inverse ode
RORG 0xA5 - FUNC 0x14 - TYPE 0x01 - Single Input Contact (Window/Door), Supply voltage monitor
shortcut description type values
SVC Supply voltage / super cap. (linear); 251 - 255 reserved for error code value 0.0-250.0 ↔ 0.0-5.0 V
CT Contact enum 1 - open
0 - closed
RORG 0xA5 - FUNC 0x20 - TYPE 0x01 - Battery Powered Actuator (BI-DIR)
direction: 1
shortcut description type values
CV Current Value value 0.0-100.0 ↔ 0.0-100.0 %
SO Service On enum 0 - off
1 - on
ENIE Energy input enabled enum 0 - false
1 - true
ES Energy storage sufficiently charged enum 0 - false
1 - true
BCAP Battery capacity; change battery next days enum 0 - false
1 - true
CCO Contact, cover open enum 0 - false
1 - true
FTS Failure Temperature sensor, out of range enum 0 - false
1 - true
DWO Detection, window open enum 0 - false
1 - true
ACO Actuator obstructed enum 0 - false
1 - true
TMP Temperature (linear) value 0.0-255.0 ↔ 0.0-40.0 °C
direction: 2
shortcut description type values
SP Valve Position or Temperature Setpoint value 0.0-100.0 ↔ 0.0-100.0 %
TMP Temperature from RCU value 0.0-255.0 ↔ 0.0-40.0 °C
RIN Run init sequence enum 0 - false
1 - true
LFS Lift set enum 0 - false
1 - true
VO Valve open / maintenance enum 0 - false
1 - true
VC Valve closed enum 0 - false
1 - true
SB Summer bit, Reduction of energy consumption enum 0 - false
1 - true
SPS Set point selection enum 0 - Valve position
1 - Temperature set point
SPN Set point inverse enum 0 - false
1 - true
RCU Select function enum 0 - RCU
1 - service on
RORG 0xA5 - FUNC 0x12 - TYPE 0x01 - Electricity
shortcut description type values
MR current value in W or cumulative value in kWh value 0.0-16777215.0 ↔ 0.0-16777215.0
TI Tariff info value 0.0-15.0 ↔ 0.0-15.0
DT Current value or cumulative value enum 0 - kWh
1 - W
DIV Divisor for value enum 0 - x/1
1 - x/10
2 - x/100
3 - x/1000
RORG 0xA5 - FUNC 0x30 - TYPE 0x03 - Digital Inputs, Wake and Temperature
shortcut description type values
TMP Temperature (linear) value 255.0-0.0 ↔ 0.0-40.0 °C
WA0 Value of wake signal enum 0 - Low
1 - High
DI3 Digital Input 3 enum 0 - Low
1 - High
DI2 Digital Input 2 enum 0 - Low
1 - High
DI1 Digital Input 1 enum 0 - Low
1 - High
DI0 Digital Input 0 enum 0 - Low
1 - High
RORG 0xA5 - FUNC 0x38 - TYPE 0x08 - Gateway
command: 1
shortcut description type values
COM Command ID enum 0-13 - Command ID {value}
TIM Time in 1/10 seconds. 0 = no time specifed value 1.0-65535.0 ↔ 0.1-6553.5 s
LCK Lock for duration time if time >0, unlimited time of no time specified. Locking may be cleared with "unlock". During lock phase no other commands will be accepted or executed enum 0 - Unlock
1 - Lock
DEL Delay or duration (if Time > 0); 0 = Duration (Execute switching command immediately and switch back after duration) 1 = Delay (Execute switching command after delay) enum 0 - Duration
1 - Delay
SW Switching command ON/OFF enum 0 - Off
1 - On
command: 2
shortcut description type values
COM Command ID enum 0-13 - Command ID {value}
EDIM Dimming value (absolute [0...255] or relative [0...100]) value 0.0-255.0 ↔ 0.0-255.0 %
RMP Ramping time in seconds, 0 = no ramping, 1...255 = seconds to 100% value 0.0-255.0 ↔ 0.0-255.0 s
EDIMR Dimming Range enum 0 - Absolute value
1 - Relative value
STR Store final value enum 0 - No
1 - Yes
SW Switching command enum 0 - Off
1 - On

VLD Telegram (0xD2)

RORG 0xD2 - FUNC 0x01 - TYPE 0x01 - Electronic switch with Local Control
command: 4
shortcut description type values
PF Power Failure enum 0 - Power Failure Detection disabled/not supported
1 - Power Failure Detection enabled
PFD Power Failure Detection enum 0 - Power Failure Detection not detected/not supported/disabled
1 - Power Failure Detection Detected
CMD Command indentifier enum 0-13 - Command ID {value}
OC Over current switch off enum 0 - Over current switch off: ready / not supported
1 - Over current switch off: executed
EL Error level enum 0 - Error level 0: hardware OK
1 - Error level 1: hardware warning
2 - Error level 2: hardware failure
3 - Error level not supported
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - Not applicable, do not use
31 - Input channel (from mains supply)
LC Local control enum 0 - Local control disabled / not supported
1 - Local control enabled
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
command: 1
shortcut description type values
CMD Command indentifier enum 0-13 - Command ID {value}
DV Dim value enum 0 - Switch to new output value
1 - Dim to new output level - dim timer 1
2 - Dim to new output level - dim timer 2
3 - Dim to new output level - dim timer 3
4 - Stop dimming
IO I/O channel enum 0-29 - Output channel {value} (to load)
30 - All output channels supported by the device
31 - Input channel (from mains supply)
OV Output value enum 0 - Output value 0% or OFF
1-100 - Output value {value}% or ON
101-126 - Not used
127 - output value not valid / not set
RORG 0xD2 - FUNC 0x05 - TYPE 0x00 - Type 0x00
command: 1
shortcut description type values
POS Vertical position enum 0-100 - Output position {value}%
127 - Do not change
ANG Rotation angle enum 0-100 - Output angle {value}%
127 - Do not change
REPO Repositioning enum 0 - Go directly to POS/ANG
1 - Go up (0%), then to POS/ANG
2 - Go down (100%), then to POS/ANG
3 - Reserved
LOCK Locking modes enum 0 - Do not change
1 - Set blockage mode
2 - Set alarm mode
3 - Reserved
4 - Reserved
5 - Reserved
6 - Reserved
7 - Deblockage
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}
command: 2
shortcut description type values
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}
command: 3
shortcut description type values
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}
command: 4
shortcut description type values
POS Vertical position enum 0-100 - Output position {value}%
127 - Do not change
ANG Rotation angle enum 0-100 - Output angle {value}%
127 - Do not change
REPO Repositioning enum 0 - Go directly to POS/ANG
1 - Go up (0%), then to POS/ANG
2 - Go down (100%), then to POS/ANG
3 - Reserved
LOCK Locking modes enum 0 - Do not change
1 - Set blockage mode
2 - Set alarm mode
3 - Reserved
4 - Reserved
5 - Reserved
6 - Reserved
7 - Deblockage
CHN Channel enum 0 - Channel 1
CMD Command Id enum 0-5 - Command ID {value}