Notifications
You must be signed in to change notification settings - Fork 17
/
Copy pathdietrich_en.yaml
253 lines (232 loc) · 13.5 KB
/
dietrich_en.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
esphome:
name: uart_dietrich
platform: ESP8266
board: d1_mini
includes:
- dietrich.h
wifi:
ssid: "ssid"
password: "secret"
# Enable logging
logger:
hardware_uart: UART1
# web server
web_server:
# Enable Home Assistant API
api:
ota:
uart:
id: uart_bus
baud_rate: 9600
tx_pin: GPIO1
rx_pin: GPIO3
# stop_bits: 1
text_sensor:
- platform: template
id: dietrich_state_txt
name: "Boiler state"
- platform: template
id: dietrich_substate_txt
name: "Boiler sub state"
sensor:
- platform: custom
lambda: |-
auto dietrich = new Dietrich(id(uart_bus));
App.register_component(dietrich);
return {dietrich->state_sensor, dietrich->sub_state_sensor, dietrich->lockout_sensor, dietrich->blocking_sensor,
dietrich->flow_temp_sensor, dietrich->return_temp_sensor, dietrich->outside_temp_sensor, dietrich->calorifier_temp_sensor,
dietrich->boiler_control_temp_sensor, dietrich->room_temp_sensor, dietrich->ch_setpoint_sensor, dietrich->dhw_setpoint_sensor, dietrich->room_temp_setpoint_sensor,
dietrich->fan_speed_setpoint_sensor, dietrich->fan_speed_sensor,
dietrich->ionisation_current_sensor, dietrich->internal_setpoint_sensor, dietrich->available_power_sensor, dietrich->pump_percentage_sensor,
dietrich->desired_max_power_sensor, dietrich->actual_power_sensor,
dietrich->demand_source_bit0_sensor, dietrich->demand_source_bit1_sensor, dietrich->demand_source_bit2_sensor, dietrich->demand_source_bit3_sensor,
dietrich->demand_source_bit4_sensor, dietrich->demand_source_bit5_sensor, dietrich->demand_source_bit6_sensor, dietrich->demand_source_bit7_sensor,
dietrich->hours_run_pump_sensor, dietrich->hours_run_3way_sensor, dietrich->hours_run_ch_sensor, dietrich->hours_run_dhw_sensor,
dietrich->power_supply_aval_hours_sensor, dietrich->pump_starts_sensor, dietrich->number_of3way_valce_cycles_sensor, dietrich->burner_start_dhw_sensor,
dietrich->total_burner_start_sensor, dietrich->failed_burner_start_sensor, dietrich->number_flame_loss_sensor,
dietrich->hydro_pressure_sensor, dietrich->control_temp_sensor, dietrich->dhw_flowrate_sensor
};
sensors:
- id: dietrich_state
on_value:
then:
- lambda: |-
if (id(dietrich_state).state==0) {id(dietrich_state_txt).publish_state("0:Standby");}
else if (id(dietrich_state).state==1) {id(dietrich_state_txt).publish_state("1:Boiler start");}
else if (id(dietrich_state).state==2) {id(dietrich_state_txt).publish_state("2:Burner start");}
else if (id(dietrich_state).state==3) {id(dietrich_state_txt).publish_state("3:Burning CH");}
else if (id(dietrich_state).state==4) {id(dietrich_state_txt).publish_state("4:Burning DHW");}
else if (id(dietrich_state).state==5) {id(dietrich_state_txt).publish_state("5:Burner stop");}
else if (id(dietrich_state).state==6) {id(dietrich_state_txt).publish_state("6:Boiler stop");}
else if (id(dietrich_state).state==7) {id(dietrich_state_txt).publish_state("7:-");}
else if (id(dietrich_state).state==8) {id(dietrich_state_txt).publish_state("8:Controlled stop");}
else if (id(dietrich_state).state==9) {id(dietrich_state_txt).publish_state("9:Blocking mode");}
else if (id(dietrich_state).state==10) {id(dietrich_state_txt).publish_state("10:Locking mode");}
else if (id(dietrich_state).state==11) {id(dietrich_state_txt).publish_state("11:Chimney mode L");}
else if (id(dietrich_state).state==12) {id(dietrich_state_txt).publish_state("12:Chimney mode h");}
else if (id(dietrich_state).state==13) {id(dietrich_state_txt).publish_state("13:Chimney mode H");}
else if (id(dietrich_state).state==14) {id(dietrich_state_txt).publish_state("14:-");}
else if (id(dietrich_state).state==15) {id(dietrich_state_txt).publish_state("15:Manual-heatdemand");}
else if (id(dietrich_state).state==16) {id(dietrich_state_txt).publish_state("16:Boiler-frost-protection");}
else if (id(dietrich_state).state==17) {id(dietrich_state_txt).publish_state("17:De-aeration");} //
else
{id(dietrich_state_txt).publish_state("999:Unknown");}
- id: dietrich_substate
on_value:
then:
- lambda: |-
if (id(dietrich_substate).state==0) {id(dietrich_substate_txt).publish_state("0:Standby");}
else if (id(dietrich_substate).state==1) {id(dietrich_substate_txt).publish_state("1:Anti-cycling");}
else if (id(dietrich_substate).state==2) {id(dietrich_substate_txt).publish_state("2:Open hydraulic valve");}
else if (id(dietrich_substate).state==3) {id(dietrich_substate_txt).publish_state("3:Pump start");}
else if (id(dietrich_substate).state==4) {id(dietrich_substate_txt).publish_state("4:Wait for burner start");}
else if (id(dietrich_substate).state==5) {id(dietrich_substate_txt).publish_state("5:-");}
else if (id(dietrich_substate).state==6) {id(dietrich_substate_txt).publish_state("6:-");}
else if (id(dietrich_substate).state==7) {id(dietrich_substate_txt).publish_state("7:-");}
else if (id(dietrich_substate).state==8) {id(dietrich_substate_txt).publish_state("8:-");}
else if (id(dietrich_substate).state==9) {id(dietrich_substate_txt).publish_state("9:-");}
else if (id(dietrich_substate).state==10) {id(dietrich_substate_txt).publish_state("10:Open external gas valve");}
else if (id(dietrich_substate).state==11) {id(dietrich_substate_txt).publish_state("11:Fan to fluegasvalve speed");}
else if (id(dietrich_substate).state==12) {id(dietrich_substate_txt).publish_state("12:Open fluegasvalve");}
else if (id(dietrich_substate).state==13) {id(dietrich_substate_txt).publish_state("13:Pre-purge");}
else if (id(dietrich_substate).state==14) {id(dietrich_substate_txt).publish_state("14:Wait for release");}
else if (id(dietrich_substate).state==15) {id(dietrich_substate_txt).publish_state("15:Burner start");}
else if (id(dietrich_substate).state==16) {id(dietrich_substate_txt).publish_state("16:VPS test");}
else if (id(dietrich_substate).state==17) {id(dietrich_substate_txt).publish_state("17:Pre-ignition");}
else if (id(dietrich_substate).state==18) {id(dietrich_substate_txt).publish_state("18:Ignition");}
else if (id(dietrich_substate).state==19) {id(dietrich_substate_txt).publish_state("19:Flame check");}
else if (id(dietrich_substate).state==20) {id(dietrich_substate_txt).publish_state("20:Interpurge");}
else if (id(dietrich_substate).state==30) {id(dietrich_substate_txt).publish_state("30:Normal internal setpoint");}
else if (id(dietrich_substate).state==31) {id(dietrich_substate_txt).publish_state("31:Limited internal setpoint");}
else if (id(dietrich_substate).state==32) {id(dietrich_substate_txt).publish_state("32:Normal power control");}
else if (id(dietrich_substate).state==33) {id(dietrich_substate_txt).publish_state("33:Gradient control level 1");}
else if (id(dietrich_substate).state==34) {id(dietrich_substate_txt).publish_state("34:Gradient control level 2");}
else if (id(dietrich_substate).state==35) {id(dietrich_substate_txt).publish_state("35:Gradient control level 3");}
else if (id(dietrich_substate).state==36) {id(dietrich_substate_txt).publish_state("36:Flame protection");}
else if (id(dietrich_substate).state==37) {id(dietrich_substate_txt).publish_state("37:Stabilisation time");}
else if (id(dietrich_substate).state==38) {id(dietrich_substate_txt).publish_state("38:Cold start");}
else if (id(dietrich_substate).state==39) {id(dietrich_substate_txt).publish_state("39:Limited power Tfg");}
else if (id(dietrich_substate).state==40) {id(dietrich_substate_txt).publish_state("40:Burner stop");}
else if (id(dietrich_substate).state==41) {id(dietrich_substate_txt).publish_state("41:Post purge");}
else if (id(dietrich_substate).state==42) {id(dietrich_substate_txt).publish_state("42:Fan to flue gas valve speed");}
else if (id(dietrich_substate).state==43) {id(dietrich_substate_txt).publish_state("43:Close flue gas valve");}
else if (id(dietrich_substate).state==44) {id(dietrich_substate_txt).publish_state("44:Stop fan");}
else if (id(dietrich_substate).state==45) {id(dietrich_substate_txt).publish_state("45:Close external gas valve");}
else if (id(dietrich_substate).state==46) {id(dietrich_substate_txt).publish_state("46:-");}
else if (id(dietrich_substate).state==47) {id(dietrich_substate_txt).publish_state("47:-");}
else if (id(dietrich_substate).state==48) {id(dietrich_substate_txt).publish_state("48:-");}
else if (id(dietrich_substate).state==49) {id(dietrich_substate_txt).publish_state("49:-");}
else if (id(dietrich_substate).state==39) {id(dietrich_substate_txt).publish_state("39:Heat exchanger protection");}
else if (id(dietrich_substate).state==60) {id(dietrich_substate_txt).publish_state("60:Pump post running");}
else if (id(dietrich_substate).state==61) {id(dietrich_substate_txt).publish_state("61:Pump stop");}
else if (id(dietrich_substate).state==62) {id(dietrich_substate_txt).publish_state("62:Close hydraulic valve");}
else if (id(dietrich_substate).state==63) {id(dietrich_substate_txt).publish_state("63:Start anti-cycle timer");}
else if (id(dietrich_substate).state==255) {id(dietrich_substate_txt).publish_state("255:Reset wait time");}
else
{id(dietrich_substate_txt).publish_state("999:Unkown Sub-State");}
- name: "Boiler lockout"
- name: "Boiler blocking"
- name: "Boiler flow temp"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler return temp"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler outside temp"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler calorifier temp"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler control temp"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler room temp"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler setpoint CH "
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler setpoint DHW"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler setpoint room"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler setpoint fanspeed"
unit_of_measurement: rpm
accuracy_decimals: 2
- name: "Boiler fanspeed"
unit_of_measurement: rpm
accuracy_decimals: 2
- name: "Boiler ionisation_current"
unit_of_measurement: "μA"
accuracy_decimals: 1
- name: "Boiler internal_setpoint"
unit_of_measurement: "%"
accuracy_decimals: 0
- name: "Boiler available_power"
unit_of_measurement: "%"
accuracy_decimals: 0
- name: "Boiler pump_percentage"
unit_of_measurement: "%"
accuracy_decimals: 0
- name: "Boiler desired_max_power"
unit_of_measurement: "%"
accuracy_decimals: 0
- name: "Boiler actual_power"
unit_of_measurement: "%"
accuracy_decimals: 0
- name: "Boiler Mod.Controller Connected"
- name: "Boiler Heat demand from Mod.Controller"
- name: "Boiler Heat demand from on/off controller"
- name: "Boiler Frost Protection"
- name: "Boiler DHW Eco"
- name: "Boiler DHW Blocking"
- name: "Boiler Anti Legionella"
- name: "Boiler DHW Heat Demand"
- name: "Boiler hours_run_pump_sensor"
unit_of_measurement: h
accuracy_decimals: 0
- name: "Boiler hours_run_3way_sensor"
unit_of_measurement: h
accuracy_decimals: 0
- name: "Boiler hours_run_ch_sensor"
unit_of_measurement: h
accuracy_decimals: 0
- name: "Boiler hours_run_dhw_sensor"
unit_of_measurement: h
accuracy_decimals: 0
- name: "Boiler power_supply_aval_hours_sensor"
unit_of_measurement: h
accuracy_decimals: 0
- name: "Boiler pump_starts_sensor"
unit_of_measurement: count
accuracy_decimals: 0
- name: "Boiler number_of3way_valce_cycles_sensor"
unit_of_measurement: count
accuracy_decimals: 0
- name: "Boiler burner_start_dhw_sensor"
unit_of_measurement: count
accuracy_decimals: 0
- name: "Boiler total_burner_start_sensor"
unit_of_measurement: count
accuracy_decimals: 0
- name: "Boiler failed_burner_start_sensor"
unit_of_measurement: count
accuracy_decimals: 0
- name: "Boiler number_flame_loss_sensor"
- name: "Boiler hydro_pressure_sensor"
unit_of_measurement: bar
accuracy_decimals: 2
- name: "Boiler control_temp_sensor"
unit_of_measurement: °C
accuracy_decimals: 2
- name: "Boiler dhw_flowrate_sensor"
unit_of_measurement: l/m
accuracy_decimals: 0
- platform: wifi_signal
name: "Boiler WiFi Signal"
update_interval: 60s
- platform: uptime
name: "Boiler Uptime"