What load was applied when you took the screenshot, 388W or 38,8W? |
Hi @SwoopX, |
Hi @SwoopX , Thanks! |
Hm, not really what I expected. Could you please try once again, but this time after deleting the device in Phoscon also physically reset the device? Meanwhile, I double check the code if something went wrong. Btw, you will not see power usage in Phoscon as we cannot do any integration there, it's closed source. |
Hi @SwoopX, |
Could you please double check the consumption value is reasonable? Might be that I made a mistake and set the comma wrongly. |
Hi @SwoopX , Thanks |
It is the total power consumed since last device reset, so it should constantly grow over time. With the LED, it takes some minutes for the value to change. |
It seems this issue is inactive / resolved. If it is not, please re-open or create another issue! |
Hi team,
Recently I bought GS SKHMP30-I1 smart plug which is only sold in Russia by one of the satellite TV operators. This smart plug is in fact produced by Heiman and is a copy of Heiman's smart plug. However, it has a different manufacturer and model id in the Basic cluster.
I was able to add this smart plug but it only supports On/Off commands, no power metering is available (I'm using Home Assistant).