RBF needs to disconnect battery from ground and battery to load. Deployment pins are in series with RBF. The umbilical DC jack will need to use the jack switch feature to connect the battery with regulators while the RBF and/or deployment switches are engaged.
Series switches need to be placed to disconnect all solar cells and batteries.