You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi Vinisha, you can only use FREEC with one control sample and one test. You can provide them in the config file, or directly in the command line. https://boevalab.inf.ethz.ch/FREEC/tutorial.html#Example
If you insist on using FREEC on many control samples, I suggest you simply merge the corresponding BAM files into one. Alternatively, you can consider the OncoCNV tool that extracts the first 3 principal components from all provided control files and creats a nice normalized CNV profile for amplicon-sequencing data.
--Hi,
is it possible to submit several control files such as:
[control]
mateFile = /work/BAMFILES/*.bam
inputFormat = BAM
mateOrientation = FR
thank you --