Values TotalE, Grid Frequency AVG and GridP3 are 0 #3

Open
apaul007 opened this issue Mar 12, 2023 · 2 comments
Open

Values TotalE, Grid Frequency AVG and GridP3 are 0 #3

apaul007 opened this issue Mar 12, 2023 · 2 comments

Comments

@apaul007
Copy link

Hello AMajland,

i am very happy about this project because it matches to my configuration for bringing values from a Danfoss TLX 12.5 into home assistant.

But i have 3 values which are zero and i think they shouldn't be.

Total Energy Production

  • Don't know what Danfoss provides there, likely all energy from start?

Grid power, L3

  • As calculated from GridP total, and Grid power L1, L2, there is a difference. This should be L3. But its always zero.

Grid Frequency AVG

  • should be around 50 Hz

Here a data output from the web interface.
I don't know if the problem is related to my Danfoss unit or if it's in the data transfer adressing.

Best regards
Andreas

Danfoss TLX

Description Value Unit Indeks
Product Number 139F0009    
Serial Number 4402G131    
Operation mode On Grid    
Total Energy Production 0.000 kWh TotalE
Inverter production this year 917.452 kWh ProdTyear
Inverter production today 3.009 kWh ProdTday
PV Voltage, input 1 512.3 V PvV1
PV Voltage, input 2 588.6 V PvV2
PV Voltage, input 3 594.6 V PvV3
PV Current, input 1 0.871 A PvA1
PV Current, input 2 0.414 A PvA2
PV Current, input 2 0.390 A PvA3
Grid frequency, L1 50.0 Hz HZ1
Grid frequency, L2 50.0 Hz HZ2
Grid frequency, L3 50.0 Hz HZ3
Grid frequency, AVG 0.0 Hz HZ
Grid current, DC L1 0 mA GridDC1
Grid current, DC L2 12 mA GridDC2
Grid current, DC L3 -4 mA GridDC3
Grid voltage, L1 232.8 V GridV1
Grid voltage, L2 232.3 V GridV2
Grid voltage, L3 232.5 V GridV3
Grid voltage, L1 (10min) 231.9 V GridV1Avg
Grid voltage, L2 (10min) 231.6 V GridV2Avg
Grid voltage, L3 (10min) 231.9 V GridV3Avg
Grid current, L1 1.693 A GridA1
Grid current, L2 1.767 A GridA2
Grid current, L3 1.734 A GridA3
Grid power, L1 322 W GridP1
Grid power, L2 339 W GridP2
Grid power, L3 0 W GridP3
Grid power 984 W GridP
Grid Energy Today, L1 0.968 kWh GridEL1day
Grid Energy Today, L2 1.035 kWh GridEL2day
Grid Energy Today, L3 1.005 kWh GridEL3day
Grid Energy Today 3.010 kWh GridEday
Operating Mode 60   OpMode
@AMajland
Copy link
Owner

AMajland commented Mar 13, 2023

I've seen this behavior on others inverters as well.

That is, some values are not returned even trough they are available in the inverter and can be seen in an export of the datalog.

If you debug the response from the inverter you might see that it returns 13 characters not the expected 22 of a normal response.

With a serial monitor running you will a timeout when waiting for the response - there are some serial print commented out that you include again.

I've been given access to an inverter that shows the same behavior but not had the time for it yet. He has even tried with 3 different com boards in his inverter and they all behave differently (All with current firmware - even uploaded it again)
image (Has panels on PV1 and PV2 so PV3 is expected to be 0. But lot of other errors)

I still plan on trying to understand what is in the short 13 char response.